VECR-220V Series

Meet our advanced Round Flow VRF Cassette, a blend of precision and comfort. With thermostat adjustments to 0.5°C or 1°C, it provides a perfectly controlled environment. An integrated Ionizer offers 96% sterilization, combating unpleasant smells and bacteria. The innovative design ensures even temperature and air distribution, while individual louver control allows for enhanced customization. The unit’s soft wind mode and high-speed fan make it perfect for high-ceiling spaces, providing efficient cooling or heating up to 4.2m. Experience precision, comfort, and hygiene with our Round Flow VRF Cassette.

0.5°C/1°C Setting Temperature Adjustment

The thermostat allows for fine-tuned temperature adjustments in increments of either 0.5°C or 1°C, facilitating accurate control for optimal comfort.

Digital Display On/Off

The displays on the indoor units can be deactivated during nighttime, fostering a more conducive atmosphere for restful sleep.

Buzzer Sound On/Off

The indoor unit’s audible alert can be disabled to avoid disturbance, thus cultivating a more tranquil environment for the user.

Ionizer Sterilization

The potent Ionizer safeguards you from unpleasant smells and harmful bacteria, boasting a sterilization circulation rate exceeding 96% for superior protection.

Dirty Filters Indicator Signal

Once the operational time hits a specified duration, the filter indicator lights up, serving as a reminder for the user to clean the filter.

360° Airflow

The innovative design, featuring a circular airflow path, guarantees even air distribution and consistent temperature throughout the space.

Individual louver control

With individual louver control, each motor can be managed separately, enabling independent control over all four louvers for enhanced flexibility.

Soft Wind Mode

In the soft wind mode, the air is directed towards the ceiling, creating a wind-free environment for enhanced comfort.

Compact Size

With heights of just 230mm for models 28 to 80, and 300mm for models 90 to 160, the Round Flow Cassette is perfectly suited for standard ceilings.

High-lift Drain Pump

The standard inclusion of a drain pump capable of elevating up to 750mm simplifies the drain piping installation process.

High Ceiling Installation

The Round Flow Cassette features an extra high fan speed designed for high-ceiling installations, capable of delivering potent cooling and heating for spaces up to 4.2m in height from the floor.

Power Supply

220-240V / 1-Phase  / 50-60Hz

Cooling Capacity

Capacity (kBtu/h): 9.6~54.5 kBtu/h 

Capacity (kW): 2.8~16.0 kW

Heating Capacity

Capacity (kBtu/h): 10.9~61.3 kBtu/h 

Capacity (kW): 3.2~18.0 kW

Sound Pressure Level

(32/31/30/28/28/26/23)~(46/44/42/41/39/38/37) dB(A)

Air Flow Volume

Cubic Meters per Hour: (801/751/711/658/637/611/542) m3/h ~ (2100/1950/1800/1750/1600/1450/1350) m3/h 

Cubic Feet per Minute: (471/442/418/387/375/359/319) cfm ~ (1235,1147,1059,1029,941,853,794) cfm

Body Net Dimensions

(W×H×D) in mm: (840 x 230 x 840) mm to (950 x 300 x 950

(WxHxD) in inches: (33 1/8 x 9 x 33 1/8) in. to (37 1/2 x 11 7/8 x 37 1/2) in.

Body Packed Dimensions

(W×H×D) in mm: (955 x 260 x 955) mm to (1050 x 335 x 1050) mm 

(WxHxD) in inches: (37 5/8 x 10 1/4 x 37 5/8) in. to (41 3/8 x 13 1/4 x 41 3/8) in. 

Body Net and Gross Weight

Net Weight:

(kg): 21.3~35.3 kg

(lbs): 46.9~77.7 lbs

Gross Weight: 

(kg): 25.8~41.2 kg

(lbs): 56.8~90.6 lbs

Panel Net Dimensions

(W×H×D) in mm: (950 x 545 x 950) mm to (1050 x 550 x 1050) mm

(WxHxD) in inches: (37 1/2 x 21 1/2 x 37 1/2) in. to (41 3/8 x 21 5/8 x 41 3/8) in. 

Panel Packed Dimensions

(W×H×D) in mm: (1035 x 90 x 1035) mm to (1115 x 100 x 1115) mm

(WxHxD) in inches: (40 3/4 x 3 1/2 x 40 3/4) in. to (43 7/8 x 3 7/8 x 43 7/8) in. 

Panel Net and Gross Weight

Net Weight:

(kg): 5.5~7.4 kg

(lbs): 12.1~16.3 lbs

Gross Weight: 

(kg): 8.2~9.7 kg

(lbs): 18.0~21.3 lbs

Unit Applications

  1. Offices: The unit could be used in various office environments, including open plan offices, individual offices, meeting rooms, etc. The fresh air intake would help maintain a comfortable and fresh environment for employees.

  2. Retail Stores: The unit can also be used in different retail environments such as supermarkets, clothing stores, or electronics stores. The ability to cool additional smaller spaces could be useful in areas where specific cooling is required, such as certain product display areas.

  3. Educational Institutions: Classrooms, libraries, and other spaces in educational institutions could benefit from the use of these units. The ability to cool an additional smaller space could be useful in larger classrooms or libraries with partitioned areas.
  4. Medical Facilities: Spaces such as waiting rooms, patient rooms, and offices in medical facilities could use these units to maintain a comfortable temperature and fresh air for patients and staff.

  5. Hotels: Hotel lobbies, rooms, conference areas, and other spaces could use these units for efficient cooling and fresh air supply.