VEHP(HA)-220V Series

Our High Static Ducted VRF Indoor Unit delivers superior HVAC performance across diverse conditions. With a static pressure range of 30Pa to 400Pa, it handles high ceilings and variable duct lengths efficiently. Key features include precise temperature control, a built-in Electronic Expansion Valve (EXV) in certain models, an easy-maintenance filter system, and a compact design requiring minimal ceiling clearance. The unit also includes a double-skin drainage pan for extra protection and a standard flange for simple duct connections. Experience a perfect blend of comfort and efficiency with this versatile HVAC solution.

Documentation

For more product information and documentation, click below

Product Features
0.5°C/1°C Setting Temperature Adjustment

You can make modifications to the preset temperature either in increments of 0.5°C or 1°C, allowing for very precise control over your comfort levels. This means that you can adjust the climate to your exact preferences, ensuring an ideal and customized thermal environment. It’s an excellent feature for those who appreciate having a precise degree of control over their surrounding conditions.

Digital Display and Buzzer Sound On/Off

During nighttime, the display of the indoor unit can be conveniently turned off, and the buzzer sound can be deactivated to avoid disturbing the user. This feature enhances the overall environment for rest, promoting a peaceful and uninterrupted sleep experience. By eliminating any visual distractions from the display and preventing any disruptive sounds from the buzzer, users can enjoy a better quality of rest and relaxation.

Innovative Puro-air Kit

The Puro-Air kit, powered by OSRAM’s UVC lamps, effectively kills bacteria, viruses, and indoor odors, promoting a healthy and safe indoor environment. It is designed to prevent UV damage to the eyes, skin, and respiratory tract.

Static Pressure 20 Steps Control

In response to varying installation conditions, the High Static Pressure Duct’s static pressure can be manipulated across as many as 20 levels using a wired remote controller. This is done to establish a comfortable atmosphere that is ideally suited to any environment. This means that regardless of the specific installation setting – be it a small room or a large hall – the system can adjust its performance to ensure optimal comfort. The 20-step control allows for fine-tuning to reach the perfect balance of temperature and airflow, hence tailoring the space to meet the specific needs of its occupants.

Multiple Fan Speeds

To cater to different indoor conditions, the DC Series offers a range of 7 indoor fan speed options, while the AC Series provides 3 indoor fan speed options. This allows users to select the appropriate fan speed setting that best suits their specific requirements. Whether it’s a need for more airflow or a desire for a quieter operation, the multiple fan speed options in both series ensure that the indoor conditions can be effectively and comfortably regulated.

Flexible Duct Design

The High Static Pressure Duct is designed to provide a broad range of static pressures, from as low as 30Pa to as high as 400Pa. This range allows it to support both short and long duct configurations, making it adaptable to various structural requirements. Furthermore, it is also capable of supplying air to spaces with high ceilings. Therefore, irrespective of the duct length or the height of the ceiling, this system can effectively deliver conditioned air, ensuring optimal circulation and temperature control throughout the space. This characteristic makes it a versatile solution for different building designs and environments.

Double-skin Drainage Pan

Utilizing a double-skin drainage pan offers an added layer of protection for ceilings. Essentially, it consists of two layers or “skins,” each acting as a protective barrier to prevent potential water leaks from reaching the ceiling. This design can be particularly important in scenarios where condensation or water drainage might pose a risk to the structural integrity or aesthetic appearance of the ceiling. By having this double protection system in place, any water that might escape the primary drainage pan is caught by the second pan, thereby safeguarding the ceiling from potential water damage.

Convenient Installation

The Electronic Expansion Valve (EXV) is integrated into the indoor units (models 71 to 160), requiring no extra links. The standard filter, encased in an aluminum frame (models 71 to 280), is easily removable from the bottom. A standard flange is included for duct connections, simplifying the installation process.

Easy Maintenance

The external static pressure can reach as high as 196Pa for models 71 to 160, and up to 280Pa for models 200 to 560. These models can supply air up to a maximum length of approximately 14m at a height of 6.5m. The body of models 71 to 160 is 420mm thick, necessitating a minimum clearance of 450mm above the ceiling for installation and maintenance.

Product Specifications
Power Supply

220-240V / 1-Phase  / 50-60Hz

Cooling Capacity

Capacity (kBtu/h): 24.2~191.1 kBtu/h 

Capacity (kW): 7.1~56.0 kW

Heating Capacity

Capacity (kBtu/h): 27.3~215.0 kBtu/h 

Capacity (kW): 8.0~63.0 kW

Sound Pressure Level

(42/41/40/40/39/39/38) dB(A) ~(59/58/57/56/55/53/51) dB(A)

Air Flow Volume

Cubic Meters per Hour: (2240/2133/2027/1920
/1813/1707/1600) m3/h ~ (7400/7000/6600/6200
/5800/5400/5000) m3/h 

Cubic Feet per Minute: (1318/1255/1192/1129/1066/1004/942) cfm ~ (4353/4118/3882/3647/3412/3176/2941) cfm

External Static Pressure

Pa: 100(30~200)~ 300(100~400)

Body Net Dimensions

(W×H×D) in mm: (965 x 423 x 690) mm to (2010 x 680 x 905) mm

(WxHxD) in inches: (38 x 16 5/8 x 27 1/8) in. to (79 1/8 x 26 3/4 x 35 5/8) in. 

Body Packed Dimensions

(W×H×D) in mm: (1090 x 440 x 768) mm to (2095 x 800 x 964)

(WxHxD) in inches: (42 7/8 x 17 3/8 x 30 1/4) in. to (82 1/2 x 31 1/2 x 38) in.

Body Net and Gross Weight

Net Weight:

(kg): 41~218 kg

(lbs): 90.2~479.6 lbs

Gross Weight: 

(kg): 47~248 kg

(lbs): 103.4~545.6 lbs

Unit Applications

  1. Large Spaces: The system is designed for large spaces like production halls, workshops, etc. where enough air flow is required. It can deliver air to even the outermost corners of the room due to its high external static pressure and air flow capabilities​1​.

  2. Commercial Buildings: The system can be used in commercial buildings that have large open areas or multiple rooms that require heating or cooling. These could include shopping centers, office buildings, hotels, or restaurants. The system’s high static pressure allows for extensive ductwork runs, making it flexible for different building layouts​2​.

  3. Residential Buildings: In large multi-story residential buildings or houses, this system can be used to provide consistent heating and cooling across different floors and rooms due to its high external static pressure and the ability to handle longer duct runs​2​.

  4. Schools and Hospitals: In schools and hospitals, where consistent and reliable temperature control is important across numerous rooms or wards, this system can be beneficial. The system’s high static pressure allows for extensive ductwork runs, making it flexible for different building layouts.